Skip to main content

Controls Integration Governance Lead - Data Center SCADA/BMS/EPMS

Job DescriptionJob DescriptionControls Integration Governance Lead – Data Center SCADA/BMS/EPMS

What outcomes will you own?

  • Every controls integration delivered on our large industrial and mission‑critical projects aligns 1:1 with EOR-approved designs and Owner standards.
  • Subcontractors meet scope, schedule, quality, and documentation commitments with no scope creep.
  • Commissioning and IST are planned, coordinated, and executed to completion with all records closed out.
  • Commercial controls—SOV, AIA billing, change orders, and forecasts—are accurate and timely.
  • ICS-layer data ingestion from BMS/EPMS into SCADA is validated and secure.

The Challenge

At Process Equipment & Controls (PEC), we deliver hyperscale data centers and other critical facilities where uptime and compliance are non-negotiable. We need a leader who can coordinate complex SCADA/BMS/EPMS integrations without writing code—someone who governs scope, mitigates risk, and ensures commissioning achieves Levels 1–5 as specified.

What You Will and Won’t Do

  • Will do: Act as PEC’s primary point of contact for SCADA, BMS, and EPMS subcontractors; orchestrate their work across phased construction, commissioning, and turnover; enforce the contract.
  • Won’t do: Perform system design or programming. Subcontractor work is limited to configuration, implementation, integration, monitoring, visualization, alarming, and data presentation.

Excluded from Subcontractor Scope (strictly enforced)

  • Control system design services
  • PLC, RTU, or OEM equipment programming
  • OEM equipment logic development
  • Relay protection configuration
  • Arc flash studies
  • Electrical construction or trade work

Integration & Coordination

  • Coordinate with PEC internal teams, other trades, commissioning agents, Owner representatives, and the EOR.
  • Validate data ingestion from BMS/EPMS through the Integration Control System (ICS) layer into SCADA.
  • Ensure SCADA configuration satisfies Owner and EOR cybersecurity requirements.
  • Confirm that infrastructure, pathways, power, network, virtualization, and baseline cybersecurity controls are provided by others per subcontract assumptions.

Commercial & Risk Management

  • Run the formal change order process for deviations from EOR-issued documents.
  • Detect and escalate scope gaps, conflicts, and emerging risks early.
  • Review subcontractor Schedule of Values (SOV) and AIA billing for compliance and accuracy.
  • Support cost forecasting, change tracking, and financial reporting for your scopes.

Commissioning, Testing & Turnover

  • Coordinate subcontractor participation in commissioning:
    • SCADA: Level 2 through Level 5 commissioning
    • BMS/EPMS: Level 1 through Level 5 commissioning
  • Support IST planning and execution.
  • Verify complete, high-quality documentation:
    • SCADA configuration documentation
    • Tag lists and point schedules
    • Alarm matrices and priorities
    • Graphics inventories
    • Test scripts and test records
    • As-built documentation
  • Ensure training, system walk-throughs, and knowledge transfer are delivered per contract.

Profile We’re Seeking

  • Track record managing large-scale industrial automation, critical facilities, or data center projects.
  • Subcontract management expertise with strong contractual and financial acumen.
  • Proven ability to enforce scope boundaries and control risk.
  • Solid understanding of SCADA, BMS, and EPMS architectures.
  • Experience leading multi-discipline systems integration efforts.
  • Clear, confident communicator with Owners, Engineers, subcontractors, and leadership.

Technical Fluency

  • SCADA platforms, including Ignition SCADA
  • Rockwell / Allen-Bradley environments
  • Protocols: BACnet, Modbus, OPC-UA, SNMP
  • Strong preference for familiarity with data center operations, redundancy, and commissioning methodologies.

Extras

  • Hyperscale data center delivery experience
  • Division 25 specifications and Integrated Systems Testing (IST)
  • Experience delivering under an Engineer of Record (EOR) model

Core Skills

  • Construction Management
  • Electrical Schematics
  • Electrical Troubleshooting Skills
  • Electrical Systems Diagnostics & Repair
  • Electrical Troubleshooting
  • Blueprint Reading
  • Basic Computer Skills

Controls Integration Governance Lead - Data Center SCADA/BMS/EPMS

Michigan City, IN 46360
Full time

Published on 04/17/2026

Share this job now