Job Description
GRAVITI ENERGY is looking to add a Graduate Research / Data Center Cooling Systems Engineer () to our team based at our Houston office, TX (remote possible for candidates). The selected candidate will be engaged in developing code for thermal engineering, HVAC system simulation modeling, and energy optimization of data center cooling systems. The role focuses on developing physics-based models and control strategies for chilled water plants, cooling towers, and economizers using tools such as Modelica and related simulation environments. The candidate will report to their immediate supervisor and work as an integral part of the engineering team to support modeling, simulation, and optimization of cooling systems. The candidate will be given structured guidance and exposure to real-world energy systems and modeling practices.
ROLES & RESPONSIBILITIES:
HVAC & Thermal System Modeling
Develop and analyze models for:
- water-cooled chillers
- cooling towers
- condenser and chilled water loops
- CRAH/CRAC systems
- waterside and airside economizers
Translate real-world data center cooling systems into:
- physics-based models
- performance curve-based models
Build modular component-level models that can be assembled into system-level simulations
Modelica & Simulation
Work with Modelica / Modelica Buildings Library to:
- model HVAC systems, central utility, chiller, and plant configurations
- simulate system dynamics and performance
- analyze system behavior under different operating conditions
Learn and apply:
- equation-based modeling
- acausal system modeling
- component-based system architecture
Control Systems & Sequences
Study and implement control strategies such as:
- Free Cooling (FC)
- Partial Mechanical Cooling (PMC)
- Full Mechanical Cooling (FMC)
Analyze:
- system transitions between operating modes
- control stability and deadband behavior
- impact of control strategies on energy efficiency
Energy Analysis & Optimization
Evaluate system performance using:
- kW/ton
- COP
- PUE
Analyze tradeoffs between:
- chiller loading
- cooling tower performance
- pump energy consumption
- Candidates must be able to read and understand recent research papers on data center cooling systems and Modelica-based modeling
- Candidates will be evaluated based on their ability to develop code for energy optimization using modelica libraries
- Mechanical Engineering
- Thermal Engineering
- Energy Systems
- Building Science
- or related field
- thermodynamics
- heat transfer
- fluid mechanics
- chilled water systems
- cooling towers
- heat exchangers
- Modelica (strongly )
- EnergyPlus / TRNSYS / similar tools
- Modelica Buildings Library
- HVAC control systems
- data center cooling systems
- data analysis
- model calibration
- Ability to work independently and as part of a team
- Strong analytical and problem-solving skills
- Ability to clearly communicate technical concepts
Interview Expectation (Important Requirement)
QUALIFICATIONS:
Candidates must be pursuing or have completed a Master’s or PhD in:
Strong understanding of:
Familiarity with HVAC systems, especially:
SKILLS:
Experience with:
Familiarity with:
Basic programming skills (Python / MATLAB) for:
ADDITIONAL REQUIREMENTS:
LOCATION:
(Remote or hybrid based on project requirements)
EQUAL OPPORTUNITY
GRAVITI ENERGY is an equal employment opportunity employer. Qualified applicants are considered without regard to , , , sex, , , , , , status as a protected veteran, or other characteristics protected by law.